Brown ring test

What is the brown ring test?

It is the confirmatory test for nitrate: 2 mL of conc. H₂SO₄ is mixed with 1 mL of the salt solution and cooled, then freshly prepared FeSO₄ solution is added slowly along the side of the tube. A dark brown ring of nitroso ferrous sulphate, [Fe(NO)]SO₄, forms at the junction of the two layers.

The brown ring test confirms the nitrate ion. It is done after conc. H₂SO₄ on the salt gives brown fumes of NO₂ (made stronger with copper turnings). The ring forms where the heavy acid layer meets the aqueous layer.

Checked against the NCERT Lab Manual (Class XII, Unit 7: Systematic Qualitative Analysis). Updated 27 Nov 2026.

  • DetectsNO₃⁻
  • Positive resultA dark brown ring forms at the junction of the acid layer and the aqueous layer.

Reagents

  • Freshly prepared ferrous sulphate (FeSO₄) solution
  • Concentrated sulphuric acid (H₂SO₄)
  • Water extract or salt solution

Procedure

  1. Take 1 mL of the salt solution (water extract) in a clean test tube.
  2. Add 2 mL of conc. H₂SO₄ slowly, mix thoroughly and cool the tube under the tap.
  3. Add freshly prepared ferrous sulphate solution dropwise along the sides of the tube, without shaking, so that it forms a layer on top of the liquid.
  4. Keep the tube still for a minute and look at the junction of the two layers. (NCERT also allows the reverse order: ferrous sulphate first, then conc. H₂SO₄ poured down the side.)

Observation

A dark brown ring forms at the junction of the acid layer and the aqueous layer.

Equations

  • NaNO₃ + H₂SO₄ → NaHSO₄ + HNO₃
  • 6FeSO₄ + 3H₂SO₄ + 2HNO₃ → 3Fe₂(SO₄)₃ + 4H₂O + 2NO
  • FeSO₄ + NO → [Fe(NO)]SO₄ (brown, nitroso ferrous sulphate)

Why it works

In strongly acidic solution Fe²⁺ reduces nitrate to nitric oxide (NO) and is itself oxidised to Fe³⁺. The NO combines with the remaining ferrous sulphate to give brown nitroso ferrous sulphate, [Fe(NO)]SO₄ (in modern notation the complex ion [Fe(H₂O)₅(NO)]²⁺). Reduction happens only where the acid is concentrated, so the colour appears as a ring at the interface.

Precautions

  • Use freshly prepared FeSO₄ solution; old solution has oxidised to Fe³⁺ and gives a poor ring.
  • Add the FeSO₄ solution (or the acid) slowly along the wall and do not shake, or the layers mix and the ring is lost.
  • Nitrite (NO₂⁻) gives a brown colour even with dilute H₂SO₄ or acetic acid; remove nitrite first (warm with NH₄Cl or add sulphamic acid) before testing for nitrate.
  • Bromide and iodide give brown Br₂ or violet I₂ with conc. H₂SO₄ which can be mistaken for the ring; remove them with silver sulphate first.
  • The complex decomposes on warming, so keep the tube cool.

Viva questions on the brown ring test

  1. What is the brown ring due to?

    Nitroso ferrous sulphate, [Fe(NO)]SO₄ (written in modern notation as the complex ion [Fe(H₂O)₅(NO)]²⁺).

  2. Why must FeSO₄ be freshly prepared?

    Ferrous sulphate is oxidised by air to ferric sulphate, and Fe³⁺ cannot reduce nitrate to NO.

  3. What is the oxidation state of iron in the brown ring complex?

    It is taken as +1, with NO bound as NO⁺.

  4. Why does the ring form only at the junction?

    Nitrate is reduced to NO only where the acid is concentrated, which is at the interface of the two layers.

  5. Which other anion gives a brown ring?

    Nitrite, and it does so even with dilute acid, so it must be removed before the nitrate test.

  6. Why does the ring disappear on shaking or warming?

    Shaking dilutes the acid and warming drives out NO, so the unstable complex breaks up.