Test for Oxalate ion (C₂O₄²⁻)
What is the confirmatory test for C₂O₄²⁻?
Calcium chloride test: the extract acidified with acetic acid gives a white ppt of calcium oxalate with CaCl₂, insoluble in ammonium oxalate and oxalic acid but soluble in dilute HCl and dilute HNO₃. This ppt dissolved in dilute H₂SO₄ and warmed decolourises very dilute KMnO₄, and the gas evolved turns lime water milky.
C₂O₄²⁻ is a conc. H₂SO₄ group anion: heating the salt with conc. H₂SO₄ gives CO and CO₂, where CO burns with a blue flame and CO₂ turns lime water milky. It is confirmed by a white calcium oxalate ppt in acetic acid that decolourises warm acidified KMnO₄.
Checked against the NCERT Lab Manual (Class XII, Unit 7: Systematic Qualitative Analysis). Updated 27 Nov 2026.
- TypeAnion (acidic radical)
- Detected byConc. H₂SO₄ test (preliminary)
- NCERT practical listIn the NCERT ion list
How to spot C₂O₄²⁻
- Oxalate salts are white; many are only slightly soluble in water.
- No reaction with dilute H₂SO₄.
- Colourless gases with conc. H₂SO₄; one burns with a blue flame.
Tests for C₂O₄²⁻: experiment, observation, inference
| Experiment | Observation | Inference |
|---|---|---|
| Heat 0.1 g of salt with conc. H₂SO₄ | Colourless, odourless gases (CO and CO₂) are evolved; CO burns with a blue flame and CO₂ turns lime water milky | C₂O₄²⁻ may be present |
| Calcium Chloride Test (confirmatory) Acidify the sodium carbonate extract with acetic acid and add calcium chloride solution | White precipitate of calcium oxalate, insoluble in ammonium oxalate and oxalic acid solution but soluble in dilute HCl and dilute HNO₃ | C₂O₄²⁻ is confirmed |
| KMnO₄ Test (confirmatory) Filter, dissolve the precipitate in dilute H₂SO₄, add very dilute KMnO₄ solution and warm; pass the gas evolved through lime water | Pink colour of KMnO₄ is discharged and the gas (CO₂) turns lime water milky | C₂O₄²⁻ is confirmed |
Equations
- Na₂C₂O₄ + H₂SO₄ (conc.) → Na₂SO₄ + CO ↑ + CO₂ ↑ + H₂O
- Ca²⁺ + C₂O₄²⁻ → CaC₂O₄ ↓ (white)
- 2MnO₄⁻ + 5C₂O₄²⁻ + 16H⁺ → 2Mn²⁺ + 10CO₂ ↑ + 8H₂O
Named tests used
Salts with C₂O₄²⁻
- Ammonium Oxalate ((NH₄)₂C₂O₄)
- Sodium Oxalate (Na₂C₂O₄)
- Potassium Oxalate (K₂C₂O₄)
- Magnesium Oxalate (MgC₂O₄)
- Barium Oxalate (BaC₂O₄)
- Zinc Oxalate (ZnC₂O₄)
- Aluminium Oxalate (Al₂(C₂O₄)₃)
- Iron(II) Oxalate (FeC₂O₄)
- Iron(III) Oxalate (Fe₂(C₂O₄)₃)
- Copper(II) Oxalate (CuC₂O₄)
- Lead(II) Oxalate (PbC₂O₄)
- Strontium Oxalate (SrC₂O₄)
- Calcium Oxalate (CaC₂O₄)
- Cobalt(II) Oxalate (CoC₂O₄)
Common mistakes
- Testing for oxalate with dilute H₂SO₄; it only reacts with conc. H₂SO₄.
- Doing the KMnO₄ test cold, so the colour fades too slowly to see.
- Reporting carbonate from CO₂ without checking for CO and the conc. acid condition.
Viva questions on C₂O₄²⁻
Which gases are given off when an oxalate is heated with conc. H₂SO₄?
Carbon monoxide and carbon dioxide.
How is CO detected?
It burns at the mouth of the tube with a blue flame.
Why does oxalate decolourise KMnO₄?
Oxalate is a reducing agent; it reduces purple MnO₄⁻ to Mn²⁺ and is oxidised to CO₂.
Why is the KMnO₄ test done warm?
The reaction is slow at room temperature; warming to about 60 °C speeds it up.
Is calcium oxalate soluble in acetic acid?
No. It dissolves in dilute HCl but not in acetic acid.
Why is acetic acid added before CaCl₂?
It prevents ppts of calcium carbonate and phosphate, which dissolve in acetic acid.
Other anions
Printing a summary? Get the one-page salt analysis chart.